[ 805.984798] nipa-hw-worker: [40/55] drivers/net/hw:ntuple.py: all 24 failed cases match known bad, skipping retry [ 806.014785] nipa-hw-worker: [40/55] drivers/net/hw:ntuple.py: rc=1 (2.1s) [ 806.014899] nipa-hw-worker: [41/55] Running drivers/net/hw:pause.py [ 806.171512] kselftest: Running tests in drivers/net/hw [ 806.773478] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 806.816428] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 807.784364] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 807.790049] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 807.811456] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 807.836665] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 807.862463] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 807.915004] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 807.955418] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 809.341871] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 809.346120] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 809.366897] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 809.394170] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 809.395315] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 809.420327] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 809.456770] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 810.380198] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 810.383978] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 810.405433] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 810.432543] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 810.433692] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 810.458520] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 810.467209] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 811.425369] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 811.429229] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 811.450727] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 811.470974] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 811.503688] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 811.526472] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 811.534708] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 812.982902] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX/TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 812.986741] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 813.049669] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 813.059775] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 813.917388] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX/TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 813.921134] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 813.998490] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 814.039834] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 814.039858] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 814.066701] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 815.052784] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 815.056559] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 815.059829] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 815.185092] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 815.208859] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 816.091089] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 816.094818] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 816.098418] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 816.229779] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 816.257656] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 817.240748] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 817.245908] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 817.248014] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 817.479227] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 817.503648] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 818.479269] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 818.485338] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 818.488502] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 818.717781] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 818.739655] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 819.621462] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 819.626770] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 819.630501] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 819.840106] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 819.861325] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 820.867451] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 820.871195] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 820.874720] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 821.073392] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 821.096313] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 822.009663] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 822.013818] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 822.016924] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 822.230481] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 822.249771] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 823.151826] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 823.155610] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 823.159685] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 823.338013] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 823.367058] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 824.294002] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 824.299852] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 824.301204] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 824.501599] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 824.523433] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 825.436170] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 825.439963] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 825.443527] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 825.638320] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 825.665002] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 826.585795] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 826.593146] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 826.618084] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 826.794854] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 826.817533] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 827.720540] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 827.724350] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 827.727349] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 827.918266] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 827.940059] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 828.862685] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 828.878720] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 828.887822] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 829.078383] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 829.101961] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 830.004887] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 830.011101] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 830.014005] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 830.213974] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 830.234904] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 831.147092] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 831.150868] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 831.153849] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 831.347963] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 831.375892] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 832.289229] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 832.292959] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 832.296324] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 832.499191] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 832.518542] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 833.535263] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 833.539226] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 833.542052] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 833.738847] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 833.764104] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 834.677410] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 834.681188] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 834.684757] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 834.878454] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 834.906266] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 835.930939] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 835.934712] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 835.938393] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 836.113851] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 836.141891] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 837.065658] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 837.070433] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 837.107238] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 837.353086] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 837.384383] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 838.311623] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 838.315443] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 838.385293] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 838.638324] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 838.665085] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 839.557670] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 839.564079] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 839.639098] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 839.895120] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 839.921441] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 840.803657] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 840.810010] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 840.841832] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1